AERCO ProtoNode Gateway
User Manual
Page 102 of 126 AERCO International, Inc. 100 Oritani Dr. Blauvelt, NY 10913 OMM-0080_0H
11/06/2014 Ph.: 800-526-0288 GF-129
Table C-6: Twelve C-Mores, Six ECS/SmartPlate, Four Modulex and Two ACS/BMS II
Equip Point Name Name
Read
Only
BACnet
Type:ID
N2
Type
N2
ID
Lon SNVT
NAME
Lon SNVT
Lon
Direction
ModBus/
Unit
Address
21
06-Over Temp
Alarm
unitstat_21
AV:216
data
float
216 nvoEcsStat21 inc count (9) Output (non-polled) 30075/21
21
07-Flow Rate flowrate_21
AV:217
data
float
217 nvoEcsFlow21 inc count (9) Output (non-polled) 30291/21
E Valve Addr 22
22
01-Cntl Output
Signal
boilerstate_22
AV:221
data
float
221 nvoEcsState22 inc count (9) Output (non-polled) 30004/22
22
02-Setpoint effectsetpt_22
AV:222
data
float
222 nvoEcsSetpt22 inc count (9) Output (non-polled) 30006/22
22
03-RmSetpt rmsetpt_22
AV:223
data
float
223 nviEcsSetptRq22 inc count (9) Input (non-polling) 40027/22
22
04-Outlet Temp
localsuptemp_2
2
AV:224
data
float
224 nvoEcsSupTmp22 inc count (9) Output (non-polled) 30002/22
22
05-FBk Sensor
Temp
localrettemp_22
AV:225
data
float
225 nvoEcsRetTmp22 inc count (9) Output (non-polled) 30290/22
22
06-Over Temp
Alarm
unitstat_22
AV:226
data
float
226 nvoEcsStat22 inc count (9) Output (non-polled) 30075/22
22
07-Flow Rate flowrate_22
AV:227
data
float
227 nvoEcsFlow22 inc count (9) Output (non-polled) 30291/22
BMS Addr 128 for C-More Controller Interface
128
01-Fire Rate Out
boilerstate_128
AV:260
data
float
228 nvoBlrState128 inc count (9) Output (non-polled) 30005/128
128
02-Header Set
Temp
effectsetpt_128
AV:261
data
float
229 nvoEffSetpt128 inc count (9) Output (non-polled) 30006/128
128
03-Net Header Set
Temp
setpt_128
AV:262
data
float
230 nviSetpt128 inc count (9) Input (non-polling) 40005/128
128
04-Header Temp
localsuptemp_1
28
AV:263
data
float
231 nvoLocSupTmp128 inc count (9) Output (non-polled) 30002/128
128
05-Outside Air
Temp
localoatemp_12
8
AV:264
data
float
232 nvoLocOATmp128 inc count (9) Output (non-polled) 30003/128
128
06-Display Code
dispcode_128
AV:265
data
float
233 nvoDispCode128 inc count (9) Output (non-polled) 30011/128